The Renewable Energy of the Year Prize goes to SULPU.

August 3rd, 2010

The Finnish Minister of Economic Affairs, Mr Mauri Pekkarinen, presented the Finnish Heat Pump Association SULPU with the Renewable Energy of the Year prize at the Savexpo Fair in Vantaa, 18 September 2009. The prize was part of the Promoting Renewable Energy series.

Photo: The prize was presented by the Minister of Economic Affairs, Mr Mauri Pekkarinen, and it was accepted by Mr Jussi Hirvonen, Chair of the Finnish Heat Pump Association and Mr Petri Koivula, Managing Director

One Million Heat Pumps in a Decade

Heat pump technology provides the heating and cooling of a building as well as the production of hot water using solar energy that has been stored either in the top layers of the earth, in water systems or in the air.
During the past few years, heat pumps have made their final breakthrough in Finland. In 2008, more than 60.000 different types of heat pumps were sold in Finland, which exceeds the previous year by a third. Ground source heat pumps provided the largest turnover, whereas air source heat pumps sold best when looking at sales numbers per piece. The new arrival on the market is the water source heat pump, which produces hot water by using outdoor air, says Mr Jussi Hirvonen, Chair of the Finnish Heat Pump Association. At present, there are approximately 250.000 heat pumps in use in Finland.

The EU requirement for increasing the use of renewable energy is challenging for Finland – a country that already at present is one of the leading countries in its use. With the optimal use of heat pumps, we should, however, be able to reach as much as a third of the 30 TWh annual increase target. I believe that one million heat pumps will be installed in Finland within the next ten years, Mr Hirvonen estimates.

 The Prize Jury’s Statement

The prize jury extends its thanks to the Finnish Heat Pump Association for its role as an active developer of the industry. SUPLU has excellently promoted the industry in various situations and contexts and has participated, for instance, in the creation of the heat-pump industry certification system in Finland.
 

Multifamily residence in Besançon

November 19th, 2009

This multifamily residence has 28 dwellings where 67 persons are living. It is heated by two brine-to-water heat pumps fed by a field of 10 borehole heat exchangers. The heated area is of 1.771 m². The two heat pumps, each with a heating capacity of 32.6 kW, are fulfilling the needs for heating and cooling. The hot tap water is provided through solar collectors in addition with electric water heaters.

General Description
Country France
City Besançon
Client name n.a.
Application area Building sector
Year of construction 2003
Heat pump type Electric heat pump
Year of installation 2003
Refrigerant R407C
Operation mode Monovalent
Purpose Heating and cooling
Heat source system Borehole heat exchanger (vertical)
Contact name Johan Ransquin
Contact E-mail johan.ransquin@ademe.fr
Contact website http://www.ademe.fr
Supported by ADEME

Project description

This residence was built in 2003. It has 28 dwellings distributed over 4 buildings, two with two storeys and two with three storeys. The heated area is of 1. 771 m². It is located in Besançon in the east centre of France, in a relatively cold climate.Multifamily residence

The insulation is good and the buildings have been awarded with a high energy performance labelling. The heating need is of 74,0 kWh/m²/year.

The heating and cooling system uses two identical non reversible heat pumps with a heating capacity of 32,6 kW each. Each heat pump is connected to 5 borehole heat exchangers with a depth of 100 m and a diameter of 32 mm.

The cooling needs are fulfilled in free cooling mode.

The hot tap water is provided by a collective system using thermal solar panels in addition with electric water heaters.

The distribution for heating and cooling is made through thermal floor for each storey. The supply water temperature in the thermal floors is 30°C for heating and 18°C for cooling.

Heat pump system

The heat pumps are brine-to-water machines with compressor driven by electricity. Each one is using five 100m-deep borehole heat exchangers as heat source.

An additional heating resistor of 15,0 kW is also available in case of very cold outdoor temperature. Since 2003, it has been used only during 8 hours in 2005.Heat pump

The heating capacity of each heat pump is 32.6 kW. The nominal electric power is 7,2 kW, fed in three-phases.

The nominal operating mode is 35°C (condenser output) and 0°C (evaporator input). The maximum temperature output at the condenser is 55°C.

Each heat pump is loaded with 6,8 kg of R407C refrigerant.

The cooling is made in free cooling mode, without the heat pumps. The cold water from the borehole heat exchangers is used in the heating/cooling floors through an intermediate heat exchanger.

The hot tap water is produced through 52 m² of solar collectors in addition with 24,0 kW of electric water heaters.
Operation experiences 

The measurement campaign was made during the complete year 2006. It was funded both by eDF and ADEME during a campaign intended to monitor the performance of ground coupled heat pumps in real conditions.

The heating system was stopped from June 8th, 2006 to October 4th, 2006. During this period, the cooling system was turned on but operated really only between July 20th and July 31st, 2006, during the hottest days of the summer.

One heat pump operated during 1.577 hours (compressor and circulator running time) and the other during 2.286 hours.

No operational problems were experienced.

Costs, economic efficiency, incentives

The operating cost can be estimated at 3,3 €/heated m² during year 2006 (based on an average electricity cost of 13 c€/kWh, excluding yearly subscription costs).

Regulations, guidelines, benchmarking

No information available

References
No information available

Characteristic values, performance data
  Design value Measured data
Year1 2003 2006
Heating capacity (kW)2 65,2  
COP (Heating, appliance)3 4,51 4,08
SPF (Heating)4   4,22
Annual heat delivery (kWh/year)   130.282
Annual CO2 emissions (kg CO2/year)5   8.145

1 Measured during January 2006 to December 2006
2 2 x 32,6 kWth
3 Appliance alone
4 Heat pump only, including all pumps and auxiliary systems SPF=2,72
5 Only indirect emissions (thus excluding possible refrigerant leaks) due to electricity consumption both for the heat pumps and the auxiliary systems. Measured during year 2006.

GROUND-MED Demonstration Project

October 6th, 2009

University of Oradea, Romania

Type of building:
Existing university building, to be renovated, comprising seminar rooms, laboratories, offices, and a workshop

Purpose:
Heating, cooling and domestic hot water (heating load: 150 kW)

System replaced:
Geothermal heating system (back-up)

Heat pump system:
Ground source heat pump (80 kW) with vertical borehole heat exchangers

Distribution system:
Wall heating system, fan coils

More infirmation:

Fact sheet: under preparation

GROUND-MED Demonstration Project

October 6th, 2009

Valencia University

Type of building:
Existing university building comprising seminar rooms, laboratories, offices and workshops

Purpose:
Heating and cooling

Heat pump system:
An existing ground source heat pump (heating capacity 17 kW, cooling capacity 15 kW) with six vertical borehole heat exchangers, will probably replaced by a Hiref heat pump (heating capacity 20 kW, cooling capacity 18 kW), system to be optimized 

Distribution system:
Fan coil units

More information:

Office building in Aachen (Case Study)

September 24th, 2009

An electrically driven ground source heat pump system is used for heating and cooling an efficient office building with flexible room concept built in the year 2002 in Aachen. The heat source consists of 28 borehole heat exchangers with a depth of 42 meters each. In summertime the building is conditioned by free cooling via the borehole heat exchangers. The control concept was optimized continuously over a five years monitoring period. In the year 2007 a Seasonal Performance Factor (SPF) of 4,3 was reached.

General Description
Country Germany
City Aachen
Client name VIKA Ingenieur GmbH
Application area Building sector
Year of construction 2002
Heat pump type Electric heat pump
Year of installation 2002
Operation mode Monovalent
Purpose Heating and cooling
Heat source system Borehole heat exchanger (vertical)
Contact name Bernhard Frohn
Contact E-mail B.Frohn@vika.de
Contact website http://www.vika.de
Supported by German Federal Ministry of Economics and Technology

 Project description

Photo: The new office building lies on the edge of a “solar housing estate” in the German town of Aachen and follows the energy specifications for the residential buildings of the estate.

The compact, four-storey office building without cellar has a north-south orientation. The large surfaced floor plan without load-bearing interior walls allows a flexible subdivision. Five parties currently use the building with approx. 100 workplaces in total. In theory, up to eight units would be possible per floor.

The reinforced concrete skeleton construction with load-bearing precast concrete facades was, for the most part, prefabricated. The building shell was therefore finished within 8 weeks and the whole building within 9 months. The high standard of insulation is in line with the construction method of a passive house but only reaches an average U-value of 0,48 W/m2K. This is, among other things, a result of the glazing in the slightly-heated staircase which, however, is located inside the insulated envelope, with a U-value of 1,6 W/m2K. The outer walls are insulated with 20 cm mineral wool and faced with square tiles ventilated at rear. The windows in the office zones consist of triple glazing in thermically separated aluminium frames (UW=0,80 W/m2K). The windows account for 41% of the facade surface area. Because of the glazing’s comparatively low g-value of approx. 50 % and cooling using thermally activated concrete surfaces, exterior shading was not installed. The annual heating requirement was calculated at 39 kWh/m2 p.a. The air-tightness test of the building envelope produced an n50-value of 0,3 per hour.

Heat pump system

An electrically driven ground source heat pump is responsible for heat generation. Each of the 28 borehole heat exchangers is 42 meters deep. The heat pump supplies a buffer storage tank (900 liters) which feeds the concrete core temperature control (CCTC) with a maximum supply temperature of 28°C. The CCTC is divided into two control circuits (north and south) on each floor.

In summer, the heat is extracted from the rooms via CCTC and released into the earth by means of the borehole heat exchangers. The minimum supply temperature in summer is 18°C. In summertime the heat pump is not in operation (free cooling).

The energy requirements for cooling and heating balance each other out - the temperatures in the soil therefore do not build up during the course of the year. The borehole heat exchangers’ water circuit can also be used for cooling and heating the supply air by means of an additional heat exchanger.

Operation experiences

  • The planners’ idea was a success. The operation of the building is both economically viable and energy efficient. The heat pump system can reach a high coefficient of performance because the temperature difference between the heat source and the supply is small, even with low outside temperatures. The energy equilibrium in the soil from the removal of heat in winter and the depositing of heat in summer also has a positive effect. However, evaluating several hundred measurement points over a five-year period was necessary to find the best control concept for operating the heat pump efficiently. For this, the accompanying EnOB monitoring was extremely important and will be continued.
  • User satisfaction in the building is very high. It must be kept in mind, however, that today’s users were both the contractors and the planners. On the other hand, this has the advantage that they have first-hand experience of the problems occurring in the operation of the building and can optimise control parameters without great dispute about responsibility or financing and without having to schedule a lot of meetings. The idea of the building going into “series production” is today being put into practice. The same building is currently being constructed in France. A variation on the design is planned for further locations.

Costs, economic efficiency, incentives

  • When constructing the building, high-quality, durable materials were used and importance was also attached to the comfort of cooling and mechanical ventilation - not necessarily the norm in offices. Nevertheless, with a net figure of 1,125 /m2 NFA (cost groups 300 and 400), the investment costs are below the average costs according to the German building cost index (BKI). This was reached because additional costs, e.g. arising from the use of geothermal energy, were compensated for by savings in other areas such as exterior sun protection. Prefabricated elements also reduced construction costs.
  • Monthly energy costs for heating, cooling, air conveyance, lighting, water heating and the lifts were amounted to 0,21 /m2 for 2005. In comparable new office buildings these costs are between 0,80 €/m2 and 1,50 /m2.
  • The monitoring campaign started in summer 2002. It was sponsored by the German Federal Ministry of Economics and Technology within the scope of the key research area, EnOB - “Energy-Optimised Construction”.

Regulations, guidelines, benchmarking

At 89 kWh/m2 p.a., the primary energy characteristic value is below the target value of 100 kWh/m2 p.a as defined in the incentive programme.

UK heat pump potential greater than previously thought

August 10th, 2009

As the UK Government is heading towards setting up a Renewable Heat Incentive, a Government commissioned study has significantly revised upwards the renewable heat potential offered by heat pumps. The document maintains that most renewable heat at low cost could come from the industrial and commercial/public sectors.

Research results aiming to improve the evidence base for developing the renewable heat incentive (RHI) have now been published. The UK Department of Energy and Climate Change has commissioned NERA Economic Consulting and AEA Technology to investigate how much renewable heat may be achievable under different scenarios, and at what cost in the UK. At the same time, the UK Government last week published its “UK Low Carbon Transition Plan”, according to which the Renewable Heat Incentive (RHI) will be introduced from April 2011.

NERA study finds increased role for heat pumps and the non-residential sector

The UK supply curve for renewable heat was constructed using a financial model of heat technologies that drew on, but also went beyond, previous work conducted for Government. The technologies covered include air-source and ground-source heat pumps, biomass individual boilers and district heating, biogas heat-only combustion and injection to the gas grid, and solar thermal.

Overall there appears to be significant potential for renewable heat to supply much of the market that currently is served by fossil fuels or electric heating. A mix of technologies is likely to be required to meet the share of renewables in heat required for the UK’s renewable energy commitments. The headline findings of the study include:

  • Heat pumps offer significant potential: Heat pumps and biomass boilers offer significant potential, in some cases at relatively low cost, while the unit cost of solar thermal was found to significantly exceed that of other renewable heat technologies. The findings differ from previous research, which ascribed a smaller role to heat pumps, and a larger role to solar thermal and heat-only biogas because of constraints on other technologies.
     
  • The industrial and commercial / public sectors generally offer lower-cost opportunities: depending on growth rates, the non-domestic sectors may be able to deliver most of the renewable heat required. This finding also differs from previous work, which indicated a higher contribution from the domestic sector instead.
  • Most important constraint to mass-market adoption of renewable heat is likely to be on the supply-side: high uncertainty with regards to the rate at which supply capacity for renewable heat technologies can grow will have a significant impact on the costs of delivering a specific share of renewable heat. The study indicates that, with sufficient subsidy, there is no limitation to demand-side potential to prevent a mass-market adoption of renewable heat. The most important constraint therefore may be on the supply-side

UK Government to introduce a Renewable Heat Incentive from April 2011

The study is published at the same time as the UK government publicised its UK Low Carbon Transition Plan, a comprehensive plan to move the UK onto a permanent low carbon footing and to maximise economic opportunities, growth and jobs. The document plots out how the UK will meet the cut in emissions set out in the budget of 34% on 1990 levels by 2020. According to the document, a new Renewable Heat Incentive (RHI) that will significantly ramp up the level of support will be available from April 2011. This will provide households, communities and businesses with payment for getting their heat from renewable sources. The scheme will cover industrial through to domestic scale heat production.

Next steps

NERA Economic Consulting is inviting comments to the study until 14 August 2009. Comments may be sent at the following address: UK_Renewable_Heat@nera.com

As mentioned in the UK Low Carbon Transition Plan, the UK Government will consult on the detailed design of the Renewable Heat Incentive later this year.

Report led by Blair recognises heat pumps’ potential

August 10th, 2009

A report led by former UK Prime Minister Tony Blair recognises heat pumps as one of the key technologies to provide significant emissions reductions. Being a technology for which pull factors for commercial investment are required already in the short run, heat pumps could achieve significant savings if deployed in 50 to 70% of buildings in the OECD by 2050.

The Climate Group has issued a report titled “Breaking the Climate Deadlock: Technology for a Low Carbon Future”. Led by former UK Prime Minister Tony Blair, the Climate Deadlock initiative seeks to bring consensus on a new and comprehensive international climate policy framework through working with world leaders in the topic.

The report concludes that the strategy that should be adopted in Copenhagen needs to focus on existing energy efficiency and renewable energy technologies, including heat pumps, along with efforts to halt deforestation, which can deliver major short-term cuts in emissions. Investing in next generation technologies - carbon capture and storage, new approaches to nuclear and solar, and emerging biotech based solutions – are other proposals that will drive down emissions through to the middle of the century.

Heat pumps can reduce 0.77 GtCO2 in 2050

Heat pumps are 1 out of 17 key technologies which according to IEA’s BLUE Map Scenario will be responsible for approximately 80% of total emissions reductions needed to 2050, equivalent to 42 GtCO2. Heat pumps have the potential to provide savings of 0.77 GtCO2 (1.6% of overall energy-related emissions reduction), if the technology is deployed in 50-70% of buildings in OECD countries by 2050.

Commercial investment in heat pump technology is needed in the short run

The total global investment costs needed for the 17 key technologies identified by the IEA between now and 2050 is “significant but manageable”, reads the report. Total annual average investment for R&D, deployment and commercialisation is estimated at close to $1 trillion for both public and private investment, an equivalent to approximately 40% of global infrastructure investment or 1.4% of world GDP.

The balance between push (RD&D Investment) and pull factors (commercial investment) for key technologies is then discussed. “Between now and 2030, RD&D push is required for most technologies to drive them towards innovation. This is especially relevant for CCS, next-generation nuclear and renewable technologies. However, in the short run, pull factors for commercial investment are also required for energy efficiency, electric and hydrogen fuel cell vehicles and heat pumps. Beyond 2030, pull factors are expected to dominate nearly all the technologies”.

For the case of heat pumps, between now and 2015, R&D, demonstration and deployment investment (market push) of about $9bn per annum is required (total investment covering both public and private sector) to drive the technology to full commercial potential. Between now and 2050, commercial investment (market push) of about $96bn per annum is required to diffuse the technology globally.

Deployment pathways for heat pumps

According to the report:

  • Further RD&D is essential to improve technical and economic performance of heat pumps by 2020. Their cost-effectiveness, energy efficiency and carbon footprint can be improved by 50% between 2020 and 2030. 50-70% of buildings in OECD will need to be fitted with heat-pumping technologies by 2050.
  • Half of the emissions savings from heat pumps are expected to be captured in developing countries and the other half in OECDc ountries.
  • Further RD&D is needed to develop more energy-efficient, sustainable and cost-effective heat pumping technologies.
  • Actions on policies are required to ensure all building codes promote energy conservation and efficiency measures.
  • Most countries should have policies that recognise the benefits of heat pumps.

About the Breaking the Climate Deadlock initiative and the Climate Group

Having been the first major head of government to bring climate change to the top of the international political agenda at the Gleneagles G8 summit in 2005, Tony Blair is now leading the ‘Breaking the Climate Deadlock’ initiative, a strategic partnership with The Climate Group, through which he is working with world leaders to bring consensus on a new and comprehensive international climate policy framework.

The Climate Group is an independent NGO working internationally with business and government leaders to advance practical policies and technologies necessary to cut global emissions and drive a prosperous low carbon economy.

Los beneficios de las bombas de calor geotérmicas

April 10th, 2009

 

 

Beneficios

 

Las bombas de calor geotérmicas ofrecen grandes beneficios:

 

·         Proporcionan calefacción y enfriamiento en forma simultánea a diferentes partes del mismo edificio.

·         Muy silenciosas. Los usuarios no se dan cuenta cuando el sistema está en operación.

·         Se pueden ajustar en diferentes zonas, donde cada zona tiene un control individual para cada habitación.

·         Mayor libertad en el diseño del edificio debido a que requieren 50-80% menos espacio para instalaciones mecánicas.

·         No hay equipo exterior que deba ocultarse, eliminando el vandalismo y las unidades en azoteas.

·         Las tuberías tienen una expectativa de vida útil de 50 años.

·         Completamente eléctricas, con lo que se evita el contratar servicios adicionales como gas  u otros combustibles.

·         Se prescinde de mantenimiento para calderas y enfriadores.

·         El geo captador de calor no requiere mantenimiento y su duración es mayor a 40 años.

 

Los sistemas geotérmicos ofrecen grandes ahorros:

 

·         Muy competitivas en inversión inicial y menor coste de operación que la mayoría de los sistemas de calefacción, ventilación y aire acondicionado.

·         Ahorros de 25-50% en consumo de energía.

·         Demanda pico más baja, con lo que es menor su coste de operación.

·         El agua se calienta con calor residual del aire acondicionado sin incurrir en coste adicional en el verano y con un ahorro substancial en el invierno.

·         Algunos proveedores de servicios ofrecen descuentos o incentivos a sus clientes que compran sistemas geotérmicos.

 

Los sistemas geotérmicos son ambientalmente amigables:

 

·         Conservan recursos naturales gracias a que el control de clima es eficiente y por lo tanto disminuye las emisiones.

·         Minimizan la destrucción de la capa de ozono gracias al uso de sistemas sellados de refrigeración, que raramente o nunca deben ser recargados.

·         Usan circuitos subterráneos para transferir calor, no requieren ventilación externa y no contaminan el aire.

·         Son muy eficientes desde el punto de vista de la energía, pues la tierra provee más del 70% de la requerida para la calefacción y el enfriamiento.

Nueva generación de tecnología de bombas de calor.

April 4th, 2009

¡La nueva generación está aquí!

 

Desde fuera parece ser lo mismo que cualquier otra bomba de calor geotérmica, pero en su interior hay nuevas características. ¡Una nueva generación de bombas de calor geotérmicas!

 

La NIBE FIGHTER 1250 es la primera bomba de calor geotérmica de velocidad controlada. Con su compresor controlado invertido, cilindro integrado de agua caliente y computadora de control inteligente es nada menos que una revolución.

 

Esto significa que la bomba siempre se auto ajusta a los requerimientos que tenga la casa o edificio en todo momento. Cuando se requiere más calor o agua caliente la salida se incrementa, y cuando se requiere una cantidad menor, disminuye su velocidad.

 

Amplíe, construya una alberca, renueve..

 

Escoger la NIBE FIGHTER 1250 tampoco significa que usted se queda atrapado en esta tecnología. Su alta eficiencia (con un máximo de 16 KW) le permitirá ampliar su casa y agregar una alberca en el futuro sin tener que incrementar la capacidad de la bomba de calor.

 

Una ventaja adicional es que requiere muy poco espacio y es fácil de instalar.

 

* Tiene un cilindro de agua caliente integrado con capacidad de 160 litros.

* Ajusta la salida entre 4.5 y 16 KW dependiendo del requerimiento real de la casa.

* El calentador integrado de inmersión de 8 KW se conecta automáticamente como operación de reserva si algo inesperado llegare a ocurrir.

* Equipada con computadora de control para una óptima y segura operación. Información clara acerca de su estado; el tiempo de operación y todas las temperaturas en la bomba de calor se muestran en su pantalla LCD.

* Reloj integrado para programar agua caliente adicional e incrementos o descensos de temperatura.

* Preparada para su conexión a un calentador de agua adicional, recuperación de ventilación, calefacción de alberca, etc.

* Puede refrescar un los días del cálido verano usando ventiladores con elementos de convección.

 

Preparada para controlar dos sistemas de calefacción a diferentes temperaturas, por ejemplo, radiadores y calefactores bajo el piso.

 

Controle y verifique la bomba de calor a través de internet o de teléfono móvil

 

Instalando un módulo de comunicación se puede aumentar o disminuir la temperatura ambiente, activar agua caliente adicional o simplemente verificar que todo funciona como debería, donde quiera que usted esté en el mundo, a través de internet o de SMS. Adicionalmente, es posible conectar una alarma de movimiento o protección contra congelación con la misma simplicidad.

 

Para mayor conveniencia, permita a una compañía de servicio hacerse cargo de la calefacción por medio del módulo de comunicación RCU 10.

 

El mejor factor anual de calor en el mercado

 

En tanto que la bomba de calor geotérmica asegura que siempre funciona en el nivel correcto de rendimiento durante todo el año, produce el máximo beneficio y abate los costes de operación.

 

Un compresor inversor controlado y las bombas de circulación implican que no se requiere respaldo, lo que a su vez conduce a una mayor eficiencia anual promedio y costes de operación más bajos.

New generation of heat pump technology.

March 29th, 2009

The New Generation is Here!

On the outside it appears to be the same as any other ground source heat pump, but inside there are even more new features. A new generation of ground source heat pump technology!

NIBE FIGHTER 1250 is the first complete, speed controlled ground source heat pump ever. With its inverter controlled compressor, integrated hot water cylinder and intelligent control computer it is nothing less than a revolution.

This means that the heat pump always automatically adjusts itself to the output requirements of the house has at any time. When more heat or hot water is required, the output increases, when not so much is needed, it drops to a lower speed.

Extend, build a pool, renovate …

Choosing NIBE FIGHTER 1250 does not mean you get caught up in the technology either. The high efficiency (max 16 kW) means that you can extend your house and attach a pool in the future without having to extend the heat pump’s capacity.

A further advantage is that it requires little space and is easy to install.

* Has an integrated 160 litre hot water cylinder.
* Adjusts the output between 4.5 and 16 kW depending on the house’s actual requirement.
* Integrated 8 kW immersion heater connects automatically as reserve operation if something unexpected should occur.
* Equipped with control computer for optimum and safe operation. Clear information about status, operation time and all temperatures in the heat pump shown on LCD display.
* Integrated clock for scheduling extra hot water and temperature lowering/increasing the flow line temperature.
* Prepared for connection to extra hot water heater, ventilation recovery, pool heating etc.
* Can cool on hot summer days using fan convectors.

Prepared for control of two heating systems at different temperatures, e.g. radiators and under floor heating.

Control and check the heat pump via Internet or mobile phone

By installing a communication module you can increase or lower the room temperature, activate extra hot water or just check that everything functions as it should, where ever you are in the world, via Internet or SMS. In addition, it is possible to connect a movement alarm or freeze protection in the same simple way.

For even more convenience, allow a service company to take care of controlling the heating via the communication module RCU 10.

The market’s best annual heat factor

As the ground source heat pump ensures that it always runs at the correct performance all year round, it produces maximum benefits and lower operational running costs.

An inverter controlled compressor and circulation pumps mean that no backup is needed, which in turn, leads to a higher annual average efficiency and lower running costs.